Inorganic Phosphorus and Potassium Are Putative Indicators of Delayed Separation of Whole Blood

Article information

Osong Public Health Res Perspect. 2015;7(2):90-95
Publication date (electronic) : 2015 November 25
doi : https://doi.org/10.1016/j.phrp.2015.11.003
aNational Biobank of Korea, Center for Genome Sciences, Korea National Institute of Health, Cheongju, Korea
bDepartment of New Health Technology Assessment Research, National Evidence-Based Healthcare Collaborating Agency, Seoul, Korea
cDepartment of Laboratory Medicine, Dankook University Medical College, Cheonan, Korea
Corresponding author. leukoso@hanmail.net
Received 2015 October 14; Revised 2015 November 12; Accepted 2015 November 16.

Abstract

Objectives

The delayed separation of whole blood can influence the concentrations of circulating blood components, including metabolites and cytokines. The aim of this study was to determine whether clinical-biochemistry analytes can be used to assess the delayed separation of whole blood.

Methods

We investigated the plasma and serum concentrations of five clinical-biochemistry analytes and free hemoglobin when the centrifugation of whole blood stored at 4°C or room temperature was delayed for 4 hours, 6 hours, 24 hours, or 48 hours, and compared the values with those of matched samples that had been centrifuged within 2 hours after whole-blood collection.

Results

The inorganic phosphorus (IP) levels in the plasma and serum samples were elevated ≥ 1.5-fold when whole-blood centrifugation was delayed at room temperature for 48 hours. Furthermore, the IP levels in the plasma samples showed excellent assessment accuracy [area under the receiver-operating-characteristic curve (AUC) > 0.9] after a 48-hour delay in whole-blood separation, and high sensitivity (100%) and specificity (95%) at an optimal cutoff point. The IP levels in the serum samples also exhibited good assessment accuracy (AUC > 0.8), and high sensitivity (81%) and specificity (100%). The potassium (K+) levels were elevated 1.4-fold in the serum samples following a 48-hour delay in whole-blood separation. The K+ levels showed excellent assessment accuracy (AUC > 0.9) following a 48-hour delay in whole-blood separation, and high sensitivity (95%) and specificity (91%) at an optimal cutoff point.

Conclusion

Our study showed that the IP and K+ levels in the plasma or serum samples could be considered as putative indicators to determine whether whole-blood separation had been delayed for extended periods.

1 Introduction

Plasma and serum samples have been used to diagnose a variety of diseases, predict prognoses, or identify disease-related biomarkers 1, 2, 3, 4. These samples are obtained by centrifugation after anticoagulation (using an anticoagulant, such as EDTA or heparin) and coagulation of whole blood, respectively [4]. Currently, the delay between collection and whole-blood centrifugation can influence the concentrations of circulating blood components, including metabolites and cytokines, due to prolonged contact with cells 5, 6, 7, 8, 9, 10. Hemolysis, which results in the release of hemoglobin and other intracellular components from red blood cells, might also occur when whole-blood processing is delayed [11]. Therefore, plasma and serum samples should be prepared as soon as possible after whole-blood collection by venipuncture [6]. However, whole-blood separation can be delayed for various reasons.

In laboratory tests (such as clinical biochemistry and hematology) routinely performed for diagnosis or prediction of prognosis in a clinical laboratory, the main causes of laboratory errors are preanalytical variables involved with biospecimen collection, processing, and storage conditions 12, 13, 14. Several studies demonstrated that delayed whole-blood separation affects the plasma and serum concentrations of biochemical analytes [e.g., alanine aminotransferase (ALT), aspartate aminotransferase (AST), inorganic phosphorus (IP), potassium (K+), and lactate dehydrogenase (LDH)] 6, 7, 8, 9. In this study, we investigated whether clinical-biochemistry analytes can be used to assess the delayed whole-blood separation. Moreover, to determine whether hemolysis influences variations in the tested analytes, we also investigated the variation of free plasma and serum hemoglobin concentrations induced by delayed whole-blood separation.

2 Materials and methods

2.1 Sample preparation

Whole-blood samples were collected from 135 participants into Vacutainer serum-separator tubes (Becton Dickinson, East Rutherford, NJ, USA) and plasma-separator tubes (Becton Dickinson). Each sample was divided into several 1.5-mL tubes (300 μL × 5 tubes), and stored at 4°C or room temperature until centrifugation for 15 minutes at 1,600g. Among the samples, one aliquot was centrifuged within 2 hours after whole-blood collection, and other aliquots were centrifuged at 4 hours, 6 hours, 24 hours, or 48 hours after the first centrifugation. (These represent “delay times” in the separation of plasma and serum.) The plasma and serum samples were separated, and then stored at −70°C before being used for clinical-biochemistry or enzyme-linked immunosorbent assay experiments.

2.2 Sample analysis

Concentrations of ALT (U/L), AST (U/L), IP (mg/dL), K+ (mmol/L), and LDH (U/L) in the plasma and serum samples were determined using an automated chemistry analyzer (Roche Modular P800 autoanalyzer; Roche Diagnostics GmbH, Mannheim, Germany) with the appropriate reagents (Roche Diagnostics) according to the recommended protocol. Free-hemoglobin concentrations (mg/dL) in the plasma and serum samples were measured using the QuantiChrom Hemoglobin Assay Kit (Bioassay Systems, Haywood, CA, USA) according to the manufacturer's recommendations. All samples were measured in duplicate.

2.3 Statistical analysis

The analyte concentrations were expressed as means ± standard deviation. To identify analytes whose concentrations increased or decreased with statistical significance in plasma and serum samples following delayed whole-blood separation, we performed a paired two-tailed t test and a repeated-measures analysis of variance using SPSS version 13.0 (SPSS Inc., Chicago, IL, USA).

To determine whether the plasma or serum concentrations of clinical-biochemistry analytes can be used for assessing delayed whole-blood separation, we carried out receiver-operating-characteristic (ROC) curve analysis using MedCalc software for Windows (MedCalc Software, Ostend, Belgium). The area under the ROC curve (AUC) values < 0.7, between 0.7 and 0.8, between 0.8 and 0.9, and > 0.9 were considered as poor, fair, good, and excellent, respectively. Statistical significance was determined as p < 0.05.

3 Results

3.1 Effect of delayed whole-blood separation on the stability of clinical-biochemistry analytes

We evaluated the concentration changes of ALT, AST, IP, K+, and LDH in the plasma and serum samples when the centrifugation of whole blood stored at 4°C or room temperature was delayed for 4 hours, 6 hours, or 24 hours as compared to the separation being performed within 2 hours after whole-blood collection (baseline; Table 1, Table 2). The concentrations of AST, K+, and LDH increased slightly (3.7–21.2%), but significantly (p < 0.05), in the plasma samples when whole-blood centrifugation was delayed at 4°C for 24 hours. Additionally, the AST and LDH concentrations changed more markedly at room temperature as compared to those at 4°C. The IP and LDH levels in the plasma were elevated > 20% relative to baseline when separation was delayed for 24 hours at room temperature. In the serum samples, the K+ and LDH concentrations increased when whole-blood centrifugation was delayed at 4°C or room temperature for 24 hours, with LDH levels increasing with delay times at both 4°C and room temperature. Moreover, the extent of the increase in K+ concentration was greater at 4°C as compared to room temperature in both the plasma and serum samples.

Concentration variations of five clinical-biochemistry analytes in the plasma samples after delayed whole-blood separation.

Concentration variations of five clinical-biochemistry analytes in the serum samples after delayed whole-blood separation.

Next, we assessed how the plasma and serum concentrations of five clinical-biochemistry analytes varied after whole-blood centrifugation was delayed at room temperature for 48 hours as compared to the concentrations in the samples separated within 2 hours after whole-blood collection (using samples distinct from those used in the aforementioned experiments). The concentrations of all analytes increased with the 48-hour delay (Figure 1). Among these, the IP level increased nearly twofold in both the plasma and serum samples. The LDH and K+ increased by 1.4-fold in the plasma and serum samples, respectively.

Figure 1

Concentration changes of five clinical-biochemistry analytes in (A) plasma and (B) serum samples when whole-blood separation was delayed at room temperature for 48 hours as compared to separation within 2 hours of whole-blood collection. * Indicates p < 0.05, calculated using a paired two-tailed t test. ALT = alanine aminotransferase; AST = aspartate aminotransferase; IP = inorganic phosphorous; K+ = potassium; LDH = lactate dehydrogenase.

3.2 Accuracy analysis of clinical-biochemistry-analyte levels in the assessment of delayed whole-blood separation

To determine whether the plasma and serum concentrations of clinical-biochemistry analytes can be used for assessing delay in whole-blood separation, we carried out ROC-curve analysis on the clinical-biochemistry analytes that increased significantly in the plasma and serum samples following a 48-hour delay in whole-blood separation (Table 3).

Accuracy of clinical-biochemistry-analyte levels in the assessment of delayed whole-blood separation at room temperature for 48 hours as compared with levels in samples separated within 2 hours of whole-blood collection.

Among the tested analytes, the plasma concentration of IP exhibited excellent assessment accuracy (AUC = 0.999) for delayed whole-blood separation. Additionally, the sensitivity (100%) and specificity (95%) were close to 100% at an optimal cutoff point of 4.3 mg/dL. The serum concentration of IP also showed good assessment accuracy (AUC = 0.856), and high sensitivity (81%) and specificity (100%) at an optimal cutoff point of 4.5 mg/dL. The K+ levels showed excellent assessment accuracy (AUC = 0.965), and high sensitivity (95%) and specificity (91%) at an optimal cutoff point of 4.7 mmol/L in the serum samples.

3.3 Change in free-hemoglobin concentration following delayed whole-blood separation

We measured the free-hemoglobin concentrations in the plasma and serum samples after whole-blood centrifugation was delayed at 4°C or room temperature for 4 hours, 6 hours, or 24 hours, and compared these values with the corresponding concentrations in samples separated within 2 hours after whole-blood collection (Table 4). The free-hemoglobin concentrations increased from 6.9% to 21.2% in both the plasma and serum samples when whole-blood separation was delayed at 4°C and room temperature for 24 hours (except in the case of the serum samples at room temperature), and tended to increase relative to the delay time.

Free-hemoglobin concentrations after delayed whole-blood separation.

We also compared the free-hemoglobin concentrations in the plasma and serum samples (samples distinct from those used previously) obtained after whole-blood centrifugation was either delayed at room temperature for 48 hours or performed within 2 hours after whole-blood collection. The concentration of free hemoglobin increased ∼1.2-fold in the plasma, but not in the serum samples. At baseline and after a 48-hour delay, the free-hemoglobin concentrations in the plasma were 46.05 ± 22.57 mg/dL and 56.39 ± 28.78 mg/dL, and in the serum were 58.90 ± 36.41 mg/dL and 57.75 ± 32.08 mg/dL, respectively (data not shown).

4 Discussion

We investigated how the plasma and serum concentrations of clinical-biochemistry analytes were changed by delayed whole-blood separation. Previous studies showed that the plasma or serum concentrations of ALT, AST, IP, K+, and LDH were slightly, but significantly, changed by delayed whole-blood separation 6, 7, 8, 9. The ALT concentration was elevated by 1.5% in serum samples obtained from whole blood stored at room temperature for 24 hours as compared to 30 minutes [8]. By contrast, the ALT concentrations in plasma samples separated from whole blood stored at 4°C or room temperature for up to 24 hours did not differ significantly from that observed in samples separated immediately after collection 6, 7. The concentrations of AST (3.0%) and LDH (8.9%) were slightly higher in serum samples prepared from whole blood stored at room temperature for 24 hours as compared to that observed in samples obtained from whole blood stored for 30 minutes [8]. The K+ concentration increased in plasma and serum samples obtained from whole blood stored at room temperature for up to 56 hours [6]. The IP concentrations changed in plasma (7.0%) and serum samples (3.8%) after whole-blood separation was delayed at room temperature for 24 hours as compared with the concentrations measured after immediate separation [9]. Our results were generally consistent with those reported previously. Additionally, we demonstrated that the IP concentration was elevated ∼2-fold in the plasma and serum samples following a 48-hour delay in separation at room temperature, and displayed high assessment accuracy, sensitivity, and specificity for a 48-hour delay in separation by ROC-curve analysis. The K+ concentration also displayed high assessment accuracy, sensitivity, and specificity in the serum samples. These findings suggest that the IP and K+ concentrations can serve as potential indicators to determine whether whole-blood centrifugation had been delayed for extended periods.

The ALT, AST, K+, and LDH concentrations are elevated in hemolytic plasma [15] or serum samples [14]. These analytes and free hemoglobin were elevated slightly, but significantly, in the plasma or serum samples when whole-blood centrifugation was delayed at 4°C or room temperature for up to 48 hours. Thus, the ALT, AST, K+, and LDH concentrations may be affected by hemolysis.

In conclusion, our findings indicate that the IP and K+ concentrations in the plasma or serum samples could be used to predict whether or not whole-blood separation was delayed for extended periods.

Conflicts of interest

The authors declare no conflicts of interest.

References

1. Adkins J.N., Monroe M.E., Auberry K.J.. A proteomic study of the HUPO Plasma Proteome Project's pilot samples using an accurate mass and time tag strategy. Proteomics 5(13)2005 Aug;:3454–3466. 16052625.
2. Anderson N.L., Anderson N.G., Pearson T.W.. A human proteome detection and quantitation project. Mol Cell Proteomics 8(5)2009 May;:883–886. 19131327.
3. Galasko D., Golde T.E.. Biomarkers for Alzheimer's disease in plasma, serum and blood—conceptual and practical problems. Alzheimers Res Ther 5(2)2013 Mar;:10. 23470193.
4. Yu Z., Kastenmuller G., He Y.. Differences between human plasma and serum metabolite profiles. PLoS One 6(7)2011 Jul;:e21230. 21760889.
5. Ayache S., Panelli M., Marincola F.M.. Effects of storage time and exogenous protease inhibitors on plasma protein levels. Am J Clin Pathol 126(2)2006 Aug;:174–184. 16891190.
6. Boyanton B.L. Jr., Blick K.E.. Stability studies of twenty-four analytes in human plasma and serum. Clin Chem 48(12)2002 Dec;:2242–2247. 12446483.
7. Clark S., Youngman L.D., Palmer A.. Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies. Int J Epidemiol 32(1)2003 Feb;:125–130. 12690023.
8. Kang H.J., Jeon S.Y., Park J.S.. Identification of clinical biomarkers for pre-analytical quality control of blood samples. Biopreserv Biobank 11(2)2013 Apr;:94–100. 23634248.
9. Oddoze C., Lombard E., Portugal H.. Stability study of 81 analytes in human whole blood, in serum and in plasma. Clin Biochem 45(6)2012 Apr;:464–469. 22285385.
10. Skogstrand K., Ekelund C.K., Thorsen P.. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples. J Immunol Methods 336(1)2008 Jul 20;:78–84. 18495149.
11. Lippi G., Blanckaert N., Bonini P.. Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med 46(6)2008 Jun;:764–772. 18601596.
12. Carraro P., Plebani M.. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem. 53(7)2007 Jul;:1338–1342. 17525103.
13. Lippi G., Guidi G.C., Mattiuzzi C.. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 44(4)2006 Apr;:358–365. 16599826.
14. Lippi G., Salvagno G.L., Montagnana M.. Influence of hemolysis on routine clinical chemistry testing. Clin Chem Lab Med 44(3)2006 Mar;:311–316. 16519604.
15. Yin P., Peter A., Franken H.. Preanalytical aspects and sample quality assessment in metabolomics studies of human blood. Clin Chem. 59(5)2013 May;:833–845. 23386698.

Acknowledgments

This work was supported by the Korea National Institute of Health, Korea Centers for Disease Control and Prevention (Grant No. 4845-301-210-13, Project No. 2013-NI74001-00). This study was approved by the Institutional Review Board (IRB) of the Korea Centers for Disease Control and Prevention (IRB No. 2013-04EXP-02-R).

Article information Continued

Figure 1

Concentration changes of five clinical-biochemistry analytes in (A) plasma and (B) serum samples when whole-blood separation was delayed at room temperature for 48 hours as compared to separation within 2 hours of whole-blood collection. * Indicates p < 0.05, calculated using a paired two-tailed t test. ALT = alanine aminotransferase; AST = aspartate aminotransferase; IP = inorganic phosphorous; K+ = potassium; LDH = lactate dehydrogenase.

Table 1

Concentration variations of five clinical-biochemistry analytes in the plasma samples after delayed whole-blood separation.

Analyte Delay time at 4°C (n = 57)
Delay time at room temperature (n = 62)
0 h (baseline) 4 h 6 h 24 h pa 0 h (baseline) 4 h 6 h 24 h pa
ALT b 23.67 ± 18.74 23.47 ± 18.40 23.26 ± 18.53 23.54 ± 18.30 0.917 24.40 ± 13.57 23.94 ± 13.68 24.03 ± 13.73 24.21 ± 13.66 0.865
(U/L) (–0.8) (–1.7) (–0.5) (–1.9) (–1.5) (–0.8)
AST b 26.54 ± 18.95 26.35 ± 17.83 26.39 ± 18.16 27.53 ± 17.79 * 0.716 24.27 ± 14.17 24.13 ± 14.08 24.37 ± 14.02 25.47 ± 14.54 * 0.639
(U/L) (–0.7) (–0.6) (+3.7) (–0.6) (+0.4) (+4.9)
IP b 3.33 ± 0.66 3.28 ± 0.67 * 3.25 ± 0.64 * 3.37 ± 0.71 0.780 3.25 ± 0.77 3.16 ± 0.77 * 3.17 ± 0.77 * 4.10 ± 1.15 * < 0.001
(mg/dL) (–1.5) (–2.6) (+1.1) (–2.8) (–2.6) (+26.3)
K+b 22.09 ± 2.32 22.42 ± 2.23 * 22.79 ± 1.96 * 26.78 ± 3.34 * < 0.001 25.35 ± 3.15 24.13 ± 3.05 * 23.77 ± 3.66 * 24.37 ± 3.56 * 0.060
(mmol/L) (+1.5) (+3.2) (+21.2) (–4.8) (–6.2) (–3.9)
LDH b 336.74 ± 100.80 336.26 ± 98.15 337.82 ± 98.65 396.61 ± 145.78 * 0.008 311.29 ± 82.07 313.58 ± 81.74 * 314.81 ± 81.03 * 382.34 ± 95.58 * < 0.001
(U/L) (–0.1) (+0.3) (+17.8) (+0.7) (+1.1) (+22.8)

* Indicates p < 0.05, calculated using a paired two-tailed t test.

ALT = alanine aminotransferase; AST = aspartate aminotransferase; IP = inorganic phosphorous; K+ = potassium; LDH = lactate dehydrogenase.

a

Significance measured using repeated-measures analysis of variance.

b

Numbers in brackets represent percentage change, with a “+” for an increase and a “–” for a decrease relative to baseline.

Table 2

Concentration variations of five clinical-biochemistry analytes in the serum samples after delayed whole-blood separation.

Analyte Delay time at 4°C (n = 55)
Delay time at room temperature (n = 58)
0 h (baseline) 4 h 6 h 24 h pa 0 h (baseline) 4 h 6 h 24 h pa
ALT b 22.64 ± 18.19 22.29 ± 18.06 * 22.29 ± 17.96 22.89 ± 17.97 0.876 22.41 ± 14.14 22.34 ± 13.91 22.16 ± 13.89 22.81 ± 14.39 0.823
(U/L) (–1.5) (–1.5) (+1.1) (–0.3) (–1.2) (+1.8)
AST b 25.13 ± 15.80 24.45 ± 15.18 * 24.58 ± 15.24 * 24.91 ± 15.02 0.837 23.40 ± 11.50 23.36 ± 11.22 23.88 ± 11.16 23.36 ± 9.55 0.819
(U/L) (–2.7) (–2.2) (–0.9) (–0.1) (+2.1) (–0.1)
IP b 3.45 ± 0.62 3.43 ± 0.62 * 3.43 ± 0.61 3.49 ± 0.60 * 0.647 3.48 ± 0.82 3.26 ± 0.81 * 3.15 ± 0.81 * 3.71 ± 1.23 0.007
(mg/dL) (–0.7) (–0.6) (+1.0) (–6.5) (–9.4) (+6.6)
K+b 4.42 ± 0.51 5.01 ± 0.52 * 5.39 ± 0.58 * 9.60 ± 2.00 * < 0.001 4.28 ± 0.46 4.24 ± 0.49 4.27 ± 0.52 4.47 ± 0.60 * 0.079
(mmol/L) (+13.4) (+22.1) (+117.3) (–0.8) (–0.2) (+4.5)
LDH b 336.93 ± 99.78 338.56 ± 97.07 339.02 ± 97.32 360.60 ± 109.54 * 0.269 318.55 ± 88.11 333.03 ± 85.03 * 335.97 ± 85.17 * 340.36 ± 81.55 * 0.213
(U/L) (+0.5) (+0.6) (+7.0) (+4.5) (+5.5) (+6.8)

* Indicates p < 0.05, calculated using a paired two-tailed t test.

ALT = alanine aminotransferase; AST = aspartate aminotransferase; IP = inorganic phosphorous; K+ = potassium; LDH = lactate dehydrogenase.

a

Significance measured using repeated-measures analysis of variance.

b

Numbers in brackets represent percentage change, with a “+” for an increase and a “–” for a decrease relative to baseline.

Table 3

Accuracy of clinical-biochemistry-analyte levels in the assessment of delayed whole-blood separation at room temperature for 48 hours as compared with levels in samples separated within 2 hours of whole-blood collection.

Sample Analyte Optimal cutoff point Area under the ROC curve Sensitivity (%) Specificity (%) p
Plasma ALT > 19.0 U/L 0.629 52.4 76.2 0.141
AST > 23.0 U/L 0.706 52.4 90.5 0.013
IP > 4.3 mg/dL 0.999 100.0 95.2 < 0.001
K+ > 22.3 mmol/L 0.765 95.2 57.1 < 0.001
LDH > 409.0 U/L 0.863 76.2 85.7 < 0.001
Serum ALT > 13.0 U/L 0.576 71.4 42.9 0.398
AST > 16.0 U/L 0.583 81.0 33.3 0.355
IP > 4.5 mg/dL 0.856 81.0 100.0 < 0.001
K+ > 4.7 mmol/L 0.965 95.2 90.5 < 0.001
LDH > 328.0 U/L 0.686 81.0 52.4 0.025

ALT = alanine aminotransferase; AST = aspartate aminotransferase; IP = inorganic phosphorous; K+ = potassium; LDH = lactate dehydrogenase; ROC = receiver operating characteristic.

Table 4

Free-hemoglobin concentrations after delayed whole-blood separation.

Storage temperature Sample Delayed time
pa
0 h (baseline) 4 h 6 h 24 h
4°C Plasma (mg/dL) 43.89 ± 18.68 48.07 ± 19.07 * 49.76 ± 21.40 * 51.05 ± 20.48 * 0.856
n = 29 b (+9.5) (+13.4) (+16.3)
Serum (mg/dL) 46.62 ± 21.06 47.71 ± 17.84 49.20 ± 19.30 56.48 ± 20.32 * 0.108
n = 27 b (+2.3) (+5.5) (+21.2)
Room temperature Plasma (mg/dL) 47.12 ± 31.35 47.33 ± 29.33 48.05 ± 28.31 50.39 ± 35.15 * 0.835
n = 68 b (+0.5) (+2.0) (+6.9)
Serum (mg/dL) 51.14 ± 33.62 47.67 ± 31.56 47.66 ± 33.84 45.90 ± 33.73 0.938
n = 68 b (–6.8) (–6.8) (–10.2)

* Indicates p < 0.05, calculated using a paired two-tailed t test.

a

Significance measured using repeated-measures analysis of variance.

b

Numbers in brackets represent percent change, with a “+” for an increase and a “–” for a decrease relative to baseline.